falcon double door strike
”
RELATED FAQS
Question
Answer
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
What electric strike can be used on a pair of doors with an L9000 lock?
Resolution:
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.:
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
What strike is required when using the 2670 Guard-X on a pair of doors?
Resolution:
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike :
What strike is used for a pair of doors with a Dor O Matic Rim device x Flushbolts on inactive door?
Resolution:
The STK45 strike is used on the inactive door leaf.:
Can 576A or 576B strikes be used on wood doors?
Resolution:
The 576A or 576B strikes can be used on wood doors but you should check with door manufacturer if it is a fire-rated door to make sure there are no conflicts.:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
What is thermal bow?
Resolution:
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...:
RU strike identification for early Corbin Russwin applications.
Resolution:
The RU lock can be requested as a retrofit for early Corbin Russwin Unit locks. Several types of strikes are offered depending on the strike conditions but two are very similar with the e...:
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
Which electric strike do I use for cylindrical locks used in a single door?
Resolution:
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application. Check the template to confirm compatibility with specific cylindrical lock model n...:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Door hitting the strike jamb?
Resolution:
If the door hits the frame (or rubs on the rabbet of the head or jamb) the frame is out of square and improperly installed. Door edge rubbing on the rabbet - shimming the hinges may resolve the...:
What strike is used for in-active leaf on pair of doors with 19-R?
Resolution:
The 571 strike is used on the in-active door leaf of a pair or on the 19-V door leaf when both doors are active per template.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.: