A purchase order must by entered through Order Entry.Part number 50-123 for Schlage and 50-123F for Falcon.  Reference the structure number (preferred) or an order number for existing mas...
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC
This only applies to the full size interchangeable cores.  The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).  Simply add (-ICX) to the end o...
The "C" indicates small format IC core, which is the only core style Falcon products.  The C987 will be provided less core unless -6, or -7 suffix is specified (6 or 7 pin core) Example:...
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
Yes. Both Schlage and Falcon SFIC mortise housings will accept 6 and 7 pin cores with no additional parts.
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
The B series accepts 6 or 7 pin small format cores when specifying with the "BD" cylinder suffix (less small format interchangeable core).  The tailpiece shown below is used for both...
Use the cylinder suffix 'T' for full size interchangeable core or the cylinder suffix 'HD' for small format interchangeable core, see Figure 1.  Small format also has a disposable core option ...
Any SFIC core will operate in the C987.  Specifically, the Schlage temporary cores are the 80-035 GRN and 80-035 BRN.
Regular Core (suffix keyway to number) Description Uncombinated Combinated 6-Pin 7-Pin 6-Pin 7-Pin Standard C646 C647 C606 C607 Best style capping CB846 CB847 CB...
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders.  Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces
Falcon SZ Series Door is the economy Steelcraft commercial grade door recommended light commercial applications when architectural specification are not needed. Options: The SZ-Series door is...
A zero bitted Falcon SFIC core is combinated for the control key to be cut at all 4's.
For all Schlage and Falcon small format interchangeable cores shipped from the factory 0-bitted, the control key will be cut to all 4's.
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC