Only the chassis components are modified for thicker door applications, the lever and spindle assemblies remain intact.
The following parts may be modified depending on the function of the lock ...
The L9000 lock can be ordered for doors greater than 1 3/4" thick. The allowable door thickness is dependent on the L lock function and how the lock is extended. All locks for exte...
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software. The software then decides what action should or should not be taken at the device.
Most locks will have a standard door range they will install on, but occasionally customers will want to use them on thicker doors. In order to do so, the extended door thick...