exit devices coordinator

RELATED FAQS

Question
Answer
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
Those holes are for mounting the coordinator mounting bracket itself.  The brackets must be drilled and tapped for the hardware you are mounting to them.
There are 2 types of door coordinators available: Bar Coordinators (Ives COR Series): Surface mounted to the bottom surface of the frame soffit. The active door lever, located nearest to th...
No, the geometry of a swing clear hinge prevents the coordinator from working correctly.  The bar style coordinator will not hold the active door open far enough for the inactive door to clear the ...
When using the 4111 with a bar style coordinator MB-mounting brackets ordered from IVES are required. The brackets wrap around the coordinator to provide a surface for mounting the parallel arm ...
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad. Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device.
The Von Duprin 372L & 370L/BE series trims are discontinued and there are no replacement for them.  The new 33A/35A series exit devices use 360L trim. 370/BE trims were used with old style 33/35...
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...
Von Duprin warrants that the product manufactured by it and delivered here under will be free of defects in material and workmanship for a period as follows: Exit devices and trim for 36 months...
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike
 A 1 1/4" cylinder with straight cam is required for the Von Duprin SD (Special Dogging) exit device option.
The cylinder cam must be inverted with the SD option to work properly.
No, the 33A is not compatible with the AD and  CO 993  chassis units. The  33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.
The baseplate assemblies are not saleable parts.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003).  At one time, the obsolete black EL ...
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
The rub plate comes standard with all bar type coordinators; COR32,42,52,60 and 72.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or "PN" device was designed for Intrinsically Safe Class 1, Division 1 applications.The device does not have a specific listing or certification pertaining to hazardous loc...
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.