exit device cycle test
”
RELATED FAQS
Question
Answer
What are cycle testing counts for exit devices?
Resolution:
ANSI grade one cycle test is 500,000, grade two is 250,000 and grade three is 100,000.:
Is the AD CO with a 993 chassis compatible with the Von Duprin 33A exit device?
Resolution:
No, the 33A is not compatible with the AD and CO 993 chassis units. The 33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.:
What are ANSI BHMA hardware grades?
Resolution:
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...:
How many times can an EL device be operated when using a PS914-2RS with battery backup?
Resolution:
The Von Duprin PS914-2RS retracts the EL or QEL device approximately 200 times with five second hold time after each pull.:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
What BHMA Grade is the Falcon 25 Series exit device?
Resolution:
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA:
Why doesn't full rotation of the AD or CO Series Exit Trim (993) outside lever fully retract the Von Duprin 98/99 Exit Device latch?
Resolution:
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ...:
692 Smart Bar trouble shooting
Resolution:
Verify power input lines have 12 or 24 volts DC. Power up the 692, several self test beeps should occur and the internal relay will cycle then it will become silent In normal operation breaking...: