ept and full surface hinge

RELATED FAQS

Question
Answer
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
EPT can be used on following hinges: Degree of the opening Hinge type Door thickness 0-180 degree Up to 5" butt hinges 1 3/4" 0-180 degree Up to 3/4" offset pivots 1 3/4" 0-130 degree 5 1/2"...
See related solution: Can an EPT be used with Cam Lift Hinges?
Cutout depends on the size of 224 hinge.  See 112HD/224HD-EPT template.  112HD/224HD continuous hinge  Center line of EPT to top of the door  83 inches  30 inches  85 inches  32 inc...