electro mechanical locks

RELATED FAQS

Question
Answer
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
Warranty Statement   3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warr...
A lock is any device which prevents access or use by requiring special knowledge or equipment. Mechanical locks are mechanical devices which secure an opening by keeping a door closed until a relea...
The following list explains the differences between the Von Duprin 47 and 48 latch assemblies. The 47 top and bottom latches have 5/8" throw latchbolts. The 48 top and bottom latches have 3/4" ...
Von Duprin 98/99 NL drive screw is located in back of the 98/99 center case assembly. NL drive screw should be left in with trim lock slide plate in up position in the 98/99 exit device with E99...
Storeroom Lock (Electrified - Fail Secure) - Outside Lever is continuously locked mechanically until unlocked by electric current. When locked, key retracts latch. Inside lever is always unlocked a...
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...
VISIT US.ALLEGION.COM/EL-SUPPORT FOR TROUBLESHOOTING VIDEO, DOWNLOADABLE GUIDE, AND INSTALLATION INSTRUCTIONS(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRI...
As of June 2011 the electrified T locks can support 12 or 24 Volts.  You do not need to specify 12 or 24 when ordering since the solenoid is capable of either voltage out of the...
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   The 6211 is used if the frame is being replaced. The 6210 is for ...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
The MA lock can be specified in a 12 or 24V DC configuration (default is 12V). Additionally, an AC power source may be used as long as a rectifier is installed in the circuit (not provided). He...
For additional details and a wiring diagram see the MA service manual page on electrical requirements here.
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application.  Check the template to confirm compatibility with specific cylindrical lock model n...
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS there ...
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EU The Schlage electrified L-Series wiring diagram can be found here and...
Applies to L9080EL/EU. L9082EL/EU (Discontinued) The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below.      ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices.