Electrified openings hardware

RELATED FAQS

Question
Answer
Knock Down (KD) frames: KD frames are designed, manufactured and supplied with integral miters which include all notches, interlocking corner tabs and slots to allow for field assembly and do not r...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
Double Egress Opening: A pair of swinging doors, each leaf which swings in the opposite direction of the other. DOORS: A pair of doors swinging in opposite directions without a vertical mullion....
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The Schlage LM9000 series lock was originally designed for use in FEMA (tornado) storm shelter openings and/or Florida Building code (hurricane) assemblies.  Doors, frames and hardware can be order...
  Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...
POCKET DOOR FRAME: A frame designed to allow a door to slide inside a pocket located within the cavity of a wall. The hinge jamb of the frame is replaced with a 2 piece jamb without a stop. I...
Lock Prep, Cylindrical Lock Prep for Knob trim; ANSIA115.2, Door Lock PrepA 160-4 lock is a cylindrical lock preparation. The lock has a 2 1/8” diameter bore through the door with a 2 3/4" backset...
Access control panel is a central repository receiving information from electrified openings and processing these signals according to predefined parameters.
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
The 900-4R is used with PS900 series power supplies and has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL devices a...
The 900-4R is used with PS900 series power supplies. The 900-4R has four independent outputs and inputs with no time delay.  You can use any of these outputs with electrified hardware including EL...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
The PS861 will not power an EL device.  The high 16Amp current of the EL requires the PS914-2RS, PS914-4RL or the older PS873-2 power supply to operate.
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...