Electric trim for von duprin all alarm
”
RELATED FAQS
Question
Answer
Is the Von Duprin E996L electric trim handing field reversible?
Resolution:
The Von Duprin E996L electric trim is field reversible. See attached 996L installation instructions on page 2 for rehanding procedure. 996L Installation Instructions:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
Can I use CD and ALK on a 98/99 series Von Duprin?
Resolution:
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK opti...:
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Resolution:
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted. During a fire alarm, the contact will open, dropping...:
Can the Von Duprin ALK exit alarm be ordered with hex dogging option on?
Resolution:
The standard exit alarm ALK devices are not available with dogging option. The device can be ordered through Engineering Special with dogging option on non fire exit devices. This special is o...:
Does the Von Duprin CX 98/9975 allow lever entry from the pull side without sounding the alarm?
Resolution:
As long as there is no door position switch wired to the CX the outside trim will work as it would on a standard 98/9975 device. :
What do I need to use a fire alarm board with a PS914?
Resolution:
The Basic PS914 power supply will not accept a 900-FA fire alarm board. 900-8F option board is required with PS914 power supply to accept 900-FA fire alarm board (900-8F is an adaptor board for...: