ELECTRIC STRIKE WITH RODS
”
RELATED FAQS
Question
Answer
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What parts are necessary to add the bottom rod/latch/strike to a 98/9927-LBR/LBR-F (less bottom rod) device?
Resolution:
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device. Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish) Bottom Latc...:
Can you use a 5547 with an electric strike?
Resolution:
The 5547 device can be ordered with an ES prefix to work in conjunction with an electric strike. This requires LBR and can only be done on non-fire rated applications. To convert an existing ...:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Why will my EL 1490 fire my latches but not hold?
Resolution:
One of the following items may cause the EL1490 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...: