electric strike used with surface vertical rod panic
”
RELATED FAQS
Question
Answer
Can an electric strike be used with a surface vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
An RX switch would only trigger the ALK Alarm Kit when the pushpad of the device is depressed.Surface Vertical Rod (SVR) Devices such as the 2227, 33/3527A, 98/9927, and 98/9957 devices could be op...:
Can the XX-V, 19-V, 24-V or 25-V extension rod be used on the bottom rod?
Resolution:
The extension rod could be used either on the top or bottom rods.:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.: