What electric strike can be used with the XP98/99 devices?
Resolution:
Von Duprin does not recommend using Electric Strikes with XP98/99 Rim Exit Devices.The design of the latchbolt creates a stronger holding force when used with the 909 or 954 mechanical strikes desi...:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
How does the latch bolt retract on the Von Duprin XP device?
Resolution:
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.:
Is there an electric strike for use with 98/9952?
Resolution:
Though not designed for use in exterior applications, the 6111 electric strike will function with the 98/9952 series exit device. Depending on the construction of the gate post, a blade sto...: