Electric strike for pair with mortise device

RELATED FAQS

Question
Answer
To use the 5547 with an electric strike you would need the ES top rod & latch part number 050656-00 and remove the bottom rod and latch. The 6213 electric strike is recommended with 5547LBR, non fi...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   The 6211 is used if the frame is being replaced. The 6210 is for ...