electric strike continuous duty

RELATED FAQS

Question
Answer
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
The Falcon EL devices can be operated in a continuous duty cycle.
The Von Duprin EL devices are rated for continuous duty.
If the solenoid of the 6000 series electric strike is powered continuously with proper voltage at room temperature, the solenoid can reach 200-220 degree Fahrenheit.
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...