elctrified lock for double acting door.
”
RELATED FAQS
Question
Answer
What LCN closer is used for double acting door?
Resolution:
The LCN 6030 is a Double Acting (or dual action) closer. Requires a "Cased Open Frame" - that means no stops formed in the frame.:
What are Overhead Concealed door closer?
Resolution:
Overhead Concealed door closers are used to provide a more aesthetic look to the opening. Concealed in either the frame or the door Offer the ability to be adjusted to maintain...:
DOUBLE ACTING
Resolution:
Door Swing:
CENTER-HUNG DOOR
Resolution:
Double Acting,:
Fire Rating for AD and CO locks
Resolution:
The AD and CO locks both have a 3 hour fire door rating. Please see URL for more info. UL Fire Rating List:
Can you mount a 6030 closer in a hollow metal frame?
Resolution:
To mount the 6030 series closer in a hollow metal frame, the frame has to be a "cased open" frame (meaning no stops formed in the frame) because the 6030 series closer is a double acting closer, wh...:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
How do you order a Senior Swing header for a 2810 on one leaf and a 2010 on the other?
Resolution:
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors. Both units contained within the same Senior Swing header. To order a paired operator with a 2810 o...:
What power supply do I need for my 2 QELA devices with LCN auto operator?
Resolution:
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...:
Do you need Double Egress arm to install a 4040SE on the Push Side of a door?
Resolution:
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...:
Why do I get error message "E701 - Programming Lock Failed" on my Hand Held Device while programming an AD lockset?
Resolution:
Update your lockset using ADFwPkg 2.19.0 or higher. This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.:
How does Dynamic Channel Switching (DCS) work on the AD-Series?
Resolution:
Setting Dynamic Channel Switching 1) Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details 2) Under “PIM Properties” and the “Edit” tab is ...: