el time delay adjustment

RELATED FAQS

Question
Answer
The PS914 x 900-2RS option board doesn't have time delay. If time delay is required specify PS914 x 900-4RL. 900-4RL provides up to 75 seconds, 5 second  increment unlock time.
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
You can not use these options together on the same device per the following reasons: QEL/EL device retracts the latch bolt of the exit device allowing entry. CX (Chexit) device locks the p...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
With the SUS connected to the AD400, in the EDIT tab there are radio communication settings "FIRST/DELAY/RETRY." FIRST - Is the first delay after the initial transmission of credential data, befor...
AD400 factory default settings when shipped are FIRST = 300 (m sec), DELAY = 200 (m sec) and RETRY = 5  
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...
The 8310-845 is now a combination "Time Delay Relay / Door Sequence" module. In 2010 the separate 8310-845 "Time Delay" module and 8310-849 “Door Sequencer” module were combined into a "common" m...