Can an EL device be ordered Fail Secure?
Resolution:
This is not possible as an EL device is an electric latch retraction and requires power to unlock the door thus only available in Fail Secure.:
How to convert the Von Duprin E996L trim from FS fail safe to FSE fail secure?
Resolution:
The E996L will ship FS fail safe from the factory if you don't tell us, You can order either FS/FSE. Can be converted to FSE fail secure. To convert the 996L to E996L (fail safe or fail secur...:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
FAIL SAFE
Resolution:
FS, EL, Electrically Locked:
Will the MPB-842 or MPB-840 power EL or QEL devices?
Resolution:
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices. A defective potted module inside the electric panic bar or defective power supply coul...:
Is Von Duprin's EL device rated for continuous duty?
Resolution:
The Von Duprin EL devices are rated for continuous duty.: