What is the power draw of a Senior Swing series operator?
Resolution:
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...:
What is the amp draw of the LCN ME and SE closers?
Resolution:
24 volt version draws 90 mAmps (0.090A). 120 volt version draws 30 mAmps (0.030A). See here for the LCN catalog sheets that contain this information (page 2 of 48). :
What is the purpose of the 900-2RS board?
Resolution:
The 900-2RS option board is used with PS914 power supply to isolate the inputs such as key pads or card readers from the outputs for EL electric exit devices. The EL draws 16 amp inrush that needs...:
What is the draw amperage for the E996L?
Resolution:
PS902 is a 2 amp power supply and each E996L electric trim draws 0.25 amps at 24VDC. You can have up to eight E996L electric trim per PS902 power supply.:
How much amperage does the QEL draw?
Resolution:
Applies only to Von Duprin QEL exit devices shipped after December 11th, 2014.1.0 amp inrush and a 0.14 amp holding current.:
What size wire and run is recommended when using a PS914-2RS?
Resolution: