DW frames specs

RELATED FAQS

Question
Answer
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc). Walls can be either wood stud or steel stud Used only for interior applicat...
This condition (toed in or toed out jambs) is usually not found until the door is installed. Frames which have toed in or toed out jambs have been installed out of tolerance. It is the resp...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
Drywall Slip-on Frame is an industry term describing a 3 sided frame designed to be installed on a wall composed of steel or wood studs with gypsum board or other facing material and is i...
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...
There is no mullion for double egress openings.  Mullions only applies to the doors that open in the same direction.
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...
It is the responsibility of the installing contractor to install all material in accordance with SDI or HMMA installation standards and tolerances. Out of square frames which are installed out of t...
Out of plumb (also referred to as twisted) frames usually cannot be adjusted. "Out of Plumb or Twisted frames (or jambs)" is a condition created by improper wall construction and/or improper insta...