dutch door label
”
RELATED FAQS
Question
Answer
Are astragals required on fire doors?
Resolution:
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...:
Can an auto operator be installed on a Dutch door?
Resolution:
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...:
What is the maximum size for a Dutch Door?
Resolution:
Maximum Dutch Door sizes are:Non Labeled = 4'0" wide X 8'0" HighLabeled = 4'0" wide X 7'2" HighSpecial sized Dutch Doors are available:Special size top and/or bottom leaves are available.When order...:
What doors are available with monorail preps?
Resolution:
Monorail cutouts are only available for non fire rated applications.:
Are the 4011 and 4021 closers the same?
Resolution:
The 4011 and 4021 use the same closer body but other components are different. The 4011 mounts "pull" side. When ordered as a 4011, it comes with a 6-3/8" rod and shoe, pull side instruction...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...:
Is a 20 minute label door a real fire door?
Resolution:
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...: