Question
Answer
Are flush bolts available on the inactive leaf of hurricane double doors with either FBC or NOA approvals?
Resolution:
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...:
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
Can the Von Duprin 8827 latch be used for flush transom doors? Does Von Duprin make a strike for surface vertical rod devices with flush transom applications?
Resolution:
Yes, the Von Duprin model 260U strike is intended for surface vertical rod devices with flush transom applications. There is also a fire rated model called the 260U-F.: