drop plate installation
”
RELATED FAQS
Question
Answer
What is the minimum top rail needed for the 4111 EDA/HEDA?
Resolution:
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
Can I use a 4040 EDA and a Glynn Johnson 100 series concealed stop together?
Resolution:
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops. The exception is: the 4041/4040XP mounted on a drop plate, and the Glynn Jo...:
How do I order a Senior Swing header?
Resolution:
How to Order: The Senior Swing header is ordered by the width of the door(s). The measurement from inside jamb to inside jamb of the frame. If the Senior Swing header is ordered the wrong len...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
MOUNTING PLATE
Resolution:
Surface Closer, Drop Plate:
How much top rail is needed on a 4041 REG/PA (Rw/PA)?
Resolution:
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...:
What drop plate is used with a 4040 Rw/PA?
Resolution:
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...:
What is the difference between a 4110-18, and a 4110-18 CUSH drop plates?
Resolution:
The 4110-18, and 4110-18 CUSH drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...:
DROP PLATE
Resolution:
Top Rail, Narrow Top Rail, Narrow Face Frame, Flush Ceiling:
Can a filler or cover plate be used to blank out a EPT prep on a fire rated frame?
Resolution:
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
FLUSH CEILING
Resolution:
Top Jamb Mout, -18G, Drop Plate, Drop Plate: