Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames.
Caution - For fire rated applications the wood door manufa...
Astragals are required on:
3 hour fire rated pairs:
Double doors - swinging in the same direction
Double Egress - swinging in opposite directions
Fire rated Dutch Doors
Fire rated 1 3/4" t...
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width).
ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly.