Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
Types of astragal offered from Steelcraft are as follows: "Z" Astragal - For information on "Z" astragal types and attachment refer to the TD Manual page 3.3.17. Most commonly used on double ...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
STC stands for Sound Transmission Class. An STC (Sound Transmission Class) is a single number rating system derived from measured values of sound transmission loss in accordance with ASTM E90 and...
Use the 575-2 strike with 9975 device on a pair of 1 3/4" thick doors with overlapping astragal mounting on the exterior of the active door. The strike lip has been cut off to eliminate any interfe...
When factory installed on GrainTech® doors: Finish Stain - YES, top caps, bottom caps and astragals are stained (prior to attachment) to match the GrainTech® door finish. GrainTech® Steel - NO, t...
SDI 114 is no longer published as an SDI performance standard. The new SDI standard for acoustical Performance is SDI 128-09 Steelcraft does offer products that have been tested in accordance wit...
All 3 hour fire rated pairs of doors do require an astragal when used without a removable hardware mullion. Pairs of doors with removable hardware mullions are treated and listed as 2 single doors...
Astragal must be applied to pull side of active leaf, since placing the stragal on the inside of the inactive leaf will interfere with the active door closing.