As of February 2016, ND locks began shipping with a new latchbolt. The new latchbolt offers substantially improved performance in adverse door conditions (ex, with heavy door loading) andis more ro...
Prior to February 2016, using ND-Series locks on hollow metal doors required the use of latch spacers which prevent the latch from "fishtailing" (back end of latch moving from side to side). Latch ...
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8". Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...
If the lock has not been ordered then specify a door thickness of 1 3/8" and a shim kit will be provided to allow installation on a thin door.
If the lock has already been ordered then order ...
Most locks will have a standard door range they will install on, but occasionally customers will want to use them on thicker doors. In order to do so, the extended door thick...
The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
The standard door range for a B600 is 1-3/4" to 2". This includes Standard cylinder, Full Size IC and Small Format IC.
Non standard door thicknesses include the following and are availa...
B500 with standard cylinders
How to order with the deadbolt:
Door thickness over 1 3/4" to 2 1/4", specify door thickness when deadbolt is ordered
Door thickness greater than 2 1/4" will req...
Schlage has conversion kits to convert the classroom L/LV9070 to the classroom security L/LV9071 and the classroom holdback L/LV9076 to the classroom security holdback L/LV9077. The...