What is the minimum and maximum door thickness for the AD and CO series locks?
Resolution:
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8". Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...:
What is the minimum top rail needed for the 4111 EDA/HEDA?
Resolution:
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame.If the top rail is less than 5-1/8" the 4110-18 drop plate is required. Minimum 2” top rail m...:
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...:
Can I order a "one piece" top rod for an 8827 for a 9' door?
Resolution:
8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...:
What is a U-Factor?
Resolution:
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products. U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...: