door closer thru-bolts
”
RELATED FAQS
Question
Answer
How to remove a double cylinder deadbolt?
Resolution:
Schlage and Falcon double cylinder deadbolts have concealed screws to prevent tampering. The two methods used to conceal the thru-bolts are using screw caps or a faceplate. Use the below instructio...:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
What size machine screws are used with thru bolts and a 2-3/4" thick door and a 4040 closer?
Resolution:
A 4040 closer mounted with thru bolts on a 2-3/4" thick door would require 1/4-20 X 3-1/2" machine screws.:
Do LCN closers come with thru bolts?
Resolution:
The standard screw pack for an LCN closer is the SRT (Self Reaming and Tapping) screw. Thru bolts are an option, but must be specified on the order. There is no charge for them, but they do need to...:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
What are the part numbers for the mounting posts and screws for an L9000 lock?
Resolution:
Mounting Posts Part Number Door Thickness L583-211 1 3/8" L583-212 1 3/4" - See note section on SL1 trim L583-213 2...: