There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
The Senior Swing has a built in circuit that controls closing speed through the motor. If the door is slamming, there must be a broken gear in the gearbox and the gearbox will need to be replaced.
The Benchmark 9100 series and Falcon 8200 Series operator will allow the door to slam if: The motor is not connected (plugged into) the controller as the closing speed is controlled by a c...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
The part number is: 1461-3071 for the door closer cylinder body.
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
The measurements from center line to centerline of the mounting holes are 2-3/8"  x  6-3/4".