Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
Can you order a 1461 cylinder only?
Resolution:
The part number is: 1461-3071 for the door closer cylinder body.:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.: