The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...
e.Primus was an electronic lock system that used iButton credentials to unlock a door.  Product was discontinued in July of 2002 with parts were available only for a short time.  Product support fo...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
With the SUS connected to the AD400, in the EDIT tab there are radio communication settings "FIRST/DELAY/RETRY." FIRST - Is the first delay after the initial transmission of credential data, befor...
AD400 factory default settings when shipped are FIRST = 300 (m sec), DELAY = 200 (m sec) and RETRY = 5  
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...