Does Von Duprin make an exit device for exterior use on gates?

RELATED FAQS

Question
Answer
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may ...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...
55 and 88 are both crossbar exit devices.  55 Series is used on narrow stile applications, 88 is for wider stile applications. See attached tables for 55 and 88 series minimum stile requirement...
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...