do parallel arm closers require drop plates
”
RELATED FAQS
Question
Answer
What drop plate is used with a 4040 Rw/PA?
Resolution:
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...:
How can I make my regular arm closer mount parallel arm?
Resolution:
This can only be done with universal, non-handed closers: 1250, 1260, 1450, 1460, 4030, 4040XP, and 4050A.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount...:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
What arm can I use for the old LCN 4030/4130 closer?
Resolution:
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit There is no closer that can replace the old 4030 series closer with the exa...:
On which closer is the fusible link arm available?
Resolution:
The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943.The 4010 Series ca...:
What are the 1460 closer arm options?
Resolution:
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...: