Direct wire alk
”
RELATED FAQS
Question
Answer
How do you specify an exit alarm ALK with a hard wire to the power supply?
Resolution:
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard feature.:
Can I bypass the circuit board on a M420 M450 or M490: Unsupported voids warranty
Resolution:
No the M400 series of mag locks may not operate direct wiring the power to the coils . Bypassing the circuit board or direct wiring the coils is not supported and voids the warranty ...:
Wiring direct to a magnet coil on 300 series Magforce lock
Resolution:
If using 12 VDC, use the following wire configuration. Tie Red and Black wires together and connect to positive. Tie Blue and Black wires together and connect to negative. If using 24 VDC, use the...:
Which direction does the Von Duprin CX 10 wire harness plug into the board?
Resolution:
Chexit devices shipped after 8-24-2015 with motor driven has a twelve wire connector wires and is keyed and can only plugged into the Chexit module in one direction. Chexit d...:
How do you wire a 4600 to sequence a double door vestibule in both directions?
Resolution:
There are 2 wiring diagrams for sequencing a double door vestibule application shown on page 13 of the 4630/4640 installation instructions.:
Will one PS902 power supply run two Von Duprin exit alarm ALK'S?
Resolution:
PS902:
Why is the Von Duprin exit alarm ALK going into alarm on it's own?
Resolution:
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...: