device center line from finished floor
”
RELATED FAQS
Question
Answer
Is the CS210 adjustable for either a 5 1/2" or 4" door prep?
Resolution:
The CS210 has a patented center-to-center adjustment that will switch from the standard 4" door prep to 5-1/2". Only these two dimensions are available.:
What is the center line of the lock case and the latchbolt on Schlage L9000 series lock?
Resolution:
These dimensions and other general lock case dimensions can be found on template L1. :
What is the difference between Von Duprin 98/9947 and 98/9948 concealed vertical rod devices?
Resolution:
They both use Template # 10320_c:
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
Why are my 1690 device bottom rod are dragging?
Resolution:
Required top and bottom rod adjustment. Top rod possibly is adjusted too short and not lifting the rod far enough to engage the latch retention which would cause bottom rod to drag floor ...:
What is the ANSI recommendation for the distance between the actuator and the door opening?
Resolution:
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...: