deadbolt stays unlocked

RELATED FAQS

Question
Answer
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...