Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
deactiave von duprin exit
”
RELATED FAQS
Question
Answer
What is the difference between the 376T and the 360T trim when it is used with Von Duprin 33/3547A exit device?
Resolution:
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
What power supply is needed for EL devices?
Resolution:
You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board will power 1 or 2 devices that do not require timing from pow...:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
Do Von Duprin Exit devices meet the 5 pound force requirement for opening an ADA handicapped door opening?
Resolution:
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...:
What parts do I need to add to the bottom rod of my existing Von Duprin 8827 LBR exit device?
Resolution:
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike:
Is there any way to lock the push side of an opening with a Von Duprin exit device?
Resolution:
You cannot lock the push side of the exit device as a panic device by design must allow exit. Any attempt to block an exit is forbidden by code.:
Is the AD CO with a 993 chassis compatible with the Von Duprin 33A exit device?
Resolution:
No, the 33A is not compatible with the AD and CO 993 chassis units. The 33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.:
Does EL or QEL conversion kit for Von Duprin exit devices contain mechanism cover plate?
Resolution:
The conversion kit does not contain a new mechanism case cover plate. If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cove...:
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :