The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
A control key is required to install or remove an interchangeable core from a housing or lever. The control key is identified by having "CONTROL" stamped on the bow. How to install and remove an i...
The old D-Series Lever used a standard lever insert similar to the pre-2002 AL-Series standard lever insert. The old D Lever insert was smaller than the AL and the two were not comp...
There was a design change in 2001 for the driver and lever insert on the AL for SFIC products. Changing the driver and/or lever insert on locks manufactured prior to 2001 will requi...
The SFIC lever insert part number prior to 2001 was the A700-022.