Only the Schlage ND-Series can be prepped to accept non-Schlage cores.
All designs are supplied with the appropriate tailpiece
Non-Schlage cores are NOT included
Lever designs available vary d...
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core)
Example: T581J IC-CR6
This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.
This only applies to the full size interchangeable cores. The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).
Simply add (-ICX) to the end o...
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder. Interchangeable core and Primus are not available with this function.
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components.
It is not possible to key SFIC and standard cylinders including Schlage FSIC into the same system. A keyway name may be shared between the two key fami...
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock.
Example: RU581J IC-SC