Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
CONTINUOUS HINGE MODIFCATIONS
”
RELATED FAQS
Question
Answer
Why is my TWP narrower than my XY hinge?
Resolution:
The TWP is a standard size across the board on continuous hinges.:
Where is common cutout for Von Duprin EPT prep in Ives 224 Continuous Hinge?
Resolution:
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template. 112HD/224HD continuous hinge Center line of EPT to top of the door 83 inches 30 inches 85 inches 32 inc...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...:
Is the material thickness of the 112HD thinner than the 224HD?
Resolution:
No, they are both the same gauge.:
What is the standard gap between a pair of doors hung with continuous hinges?
Resolution:
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...:
What hinges can be used on tornado doors?
Resolution:
The following hinges are available on Paladin series doors and frames: Butt hinges - 4 1/2" or 5" ball bearing type either standard or heavy duty Continuous hinges - full ...: