The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
9847-F Series ,9947-F Series, 98/9947WDC-F, 5547-F, 5547WDC-F, 8847-F
There are two main differences:The bottom latches are differentThe Von Duprin 98/9947 concealed vertical rod device covers up to 1/4" undercutThe Von Duprin 98/9948 concealed vertical rod device co...
They both use Template # 10320_c
An exit device with rods concealed in the door and connected to top and bottom latches.
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
 8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...
47, 5547, 8847, 9447, 9547, 9847, 9947, 3347A, 3547A, 9848, 9948, 9847, 9947, 9847WDC, 9947WDC, 8847-F, 5547, 5547WDC
9827-F Series ,9827-F Series, 8827-F, 2227-F
The 9475 mortise device is for single door only. 
For 33/3549A and 98/9949 cable devices shipped from the factory AFTER 7-15-2016:The door opening height must be specified during order entry. The 33/3549A and 98/9949 cable devices are availab...
 
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Pr...
Use Schlage B520-295 cam with the Falcon 986 conventional cylinder. Use Falcon A12667-013-00 with the Falcon C987 SFIC housing.
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.