Concealed vertical cable

RELATED FAQS

Question
Answer
For 33/3549A and 98/9949 cable devices shipped from the factory AFTER 7-15-2016:The door opening height must be specified during order entry. The 33/3549A and 98/9949 cable devices are availab...
 
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built Befo...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Primus  B520-730  B520-731  B520-2...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
For standard (non-IC) cylinders, use the Falcon #4 straight cam For IC cylinders, use the Falcon #5 cam 
The Falcon Monarch 18-R-EO device can be converted in the field to the 18-R-L by purchasing three parts. The following items are required to convert the device.  812L or 816L lever tri...
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
All hardware options (available on standard door) are available on GrainTech® doors. Available hardware are covered in the Steelcraft Price Manual. GrainTech® doors can be prepped for the Von Dupr...
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...
On May 1, 2013 the LM9000 lock series was discontinued and replaced with the LM9300 Multipoint Lock series. See related solution for information on current multipoint offering: What is th...
The Schlage LM9000 Multipoint Solution was a three-point locking assembly that was UL approved to FEMA 361 and FEMA 320 guidelines for outswing doors, and met ANSI ICC 500 for tornad...
RPD, VRPD, Rim Exit, Mortise Exit, Vertical Rod Exit, Surface Vertival Rod, Concealed Vertical Rod
There are two main differences:The bottom latches are differentThe Von Duprin 98/9947 concealed vertical rod device covers up to 1/4" undercutThe Von Duprin 98/9948 concealed vertical rod device co...
They both use Template # 10320_c
The "500" Series trim in general (510L, 511L, 512's, & 513K) will work with all 25 series devices and are not device specific.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
An exit device with rods concealed in the door and connected to top and bottom latches.
47, 5547, 8847, 9447, 9547, 9847, 9947, 3347A, 3547A, 9848, 9948, 9847, 9947, 9847WDC, 9947WDC, 8847-F, 5547, 5547WDC
9847-F Series ,9947-F Series, 98/9947WDC-F, 5547-F, 5547WDC-F, 8847-F
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: Remove ...
The power to the Von Duprin potted module also called potted circuit breaker is non polarized.