Will the new concealed vertical cable system work with any door height?
Resolution:
:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
Can I use an AD or CO - 993 Exit Trim with a Von Duprin 98/99 Concealed Vertical Rod exit device on a wood door?
Resolution:
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
What is the Falcon cam designation for use on 25 series trims?
Resolution:
For standard (non-IC) cylinders, use the Falcon #4 straight cam For IC cylinders, use the Falcon #5 cam :
How do you change the Von Duprin 990TP trim to NL function?
Resolution:
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...:
Are GrainTech doors available with hardware preps?
Resolution:
All hardware options (available on standard door) are available on GrainTech® doors. Available hardware are covered in the Steelcraft Price Manual. GrainTech® doors can be prepped for the Von Dupr...:
How to adjust the 9847/9947 or 9848/9948 rod adjustment?
Resolution:
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...:
Does Von Duprin supply the 9875, 9975, 9875-F and 9975-F mortise exit devices with NL-OP trim function?
Resolution:
For night latch function with pull by others, the 98/99 series mortise exit device should be ordered as NL less trim, e.g., 9875NL-L/TRIM. We will furnish a device only, and the mortise cyl...:
What is the LM9000 mortise lock?
Resolution:
The Schlage LM9000 Multipoint Solution was a three-point locking assembly that was UL approved to FEMA 361 and FEMA 320 guidelines for outswing doors, and met ANSI ICC 500 for tornad...:
EXIT HARDWARE
Resolution:
RPD, VRPD, Rim Exit, Mortise Exit, Vertical Rod Exit, Surface Vertival Rod, Concealed Vertical Rod:
What is the difference between Von Duprin 98/9947 and 98/9948 concealed vertical rod devices?
Resolution:
They both use Template # 10320_c:
Will a 510L or 511L trim work for a vertical, mortise, concealed, or rim device when ordering the trim by itself?
Resolution:
The "500" Series trim in general (510L, 511L, 512's, & 513K) will work with all 25 series devices and are not device specific.:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Where is the template for the 718 trims made after 2/28/2011 for Falcon/Monarch concealed vertical rod devices?
Resolution:
Templates for current 718 series trim can also be found on Falcon website:
Concealed vertical rod exit device
Resolution:
An exit device with rods concealed in the door and connected to top and bottom latches.:
CONCEALED VERTICAL ROD
Resolution:
CV:
CONCEALED VERTICAL ROD DEVICE
Resolution:
47, 5547, 8847, 9447, 9547, 9847, 9947, 3347A, 3547A, 9848, 9948, 9847, 9947, 9847WDC, 9947WDC, 8847-F, 5547, 5547WDC:
FIRE RATED CONCEALED VERTICAL ROD FIRE DEVICE
Resolution:
9847-F Series ,9947-F Series, 98/9947WDC-F, 5547-F, 5547WDC-F, 8847-F:
How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Is the power to the Von Duprin potted module polarized?
Resolution:
The power to the Von Duprin potted module also called potted circuit breaker is non polarized.: