co lock minimun width sytle
”
RELATED FAQS
Question
Answer
What is the minimum rose dimension that can be used with a Steelcraft 61L lock preparation?
Resolution:
The minimum rose that can be used on the 61L (ANSI/BHMA A156.115.18) preparation is 3 7/16".Steelcraft's 61L lock prep (often referred to as the "Squashed Turtle lock prep") is designed for Bored L...:
Can a Senior Swing 9550 be mounted on an unequal pair of doors?
Resolution:
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application - For Product Shipped...:
What is the minimum door width for a 98/99 Rim device with 4954 mullion?
Resolution:
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is 26.687" (26 11/16"):
What is the low battery threshold for the AD and CO Locks?
Resolution:
CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...:
What is the minimum and maximum door thickness for the AD and CO series locks?
Resolution:
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8". Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...:
MA lock case dimensions.
Resolution:
See below for commonly requested dimensions on the MA lock. Dimensions not found in other literature have a square around them. CL refers to "Centerline". :
Can a door have an InPact device and glass lights?
Resolution:
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...:
What is the minimum dimension from the edge of the door to a glass light cutout?
Resolution:
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...:
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
What is the recommended Stile Size for AD and CO?
Resolution:
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.:
Will the SUS pull the audit trail from the CL Series, CM Series, CO Series or AD Series locksets?
Resolution:
When the SUS and HHD are used in the “Auto Update” mode, the audit info will be automatically gathered each time the SUS is successfully connected with a lock.:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...: