Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
closed back strike
”
RELATED FAQS
Question
Answer
What electric strike can be used on a pair of doors with an L9000 lock?
Resolution:
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.:
Can I set up the CT5000 to remotely unlock a door?
Resolution:
When the switch changes state (e.g., from open to closed), the CT5000 will change the state of the Strike relay.:
FRAME ELEMENTS
Resolution:
Head, Jamb, Hinge Jamb, Strike Jamb, Blank Jamb, Mullion, Open sSection, Closed Section; frame componets:
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...:
What strike is required when using the 2670 Guard-X on a pair of doors?
Resolution:
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike :
Why doesn't full rotation of the AD or CO Series Exit Trim (993) outside lever fully retract the Von Duprin 98/99 Exit Device latch?
Resolution:
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ...:
OPEN BACK STRIKE
Resolution:
OBS, 576A, 576B:
What is the part number for the 6210 spring and lip replacement package?
Resolution:
You can replace the 6210 spring and lip, part number 050940-00.:
Will the 6210 work with the Best 45H? If not is there another electric strike that is compatible.
Resolution:
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...:
Are the 6000 series strikes field selectable for 12 or 24 VDC?
Resolution:
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other.:
Is the device centerline of the 9975, the same as the centerline of the 6223 strike?
Resolution:
The centerline of 6223 is the same as the centerline of the mortise latch bolt. So the centerline of the mortise latch bolt or center line of the 6223 is 15/32" above the centerline of the device.:
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Do we have an electric strike for use w/ a mortise lock w/ deadbolt for wood frame?
Resolution:
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.:
Is a rectifier needed to change AC to DC on Von Duprin 6000 series electric strikes?
Resolution:
The strike will always be DC. By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.:
What electric strike will work with mortise lock and aluminum 1 1/2" faced frame?
Resolution:
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame. Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
How to determine the voltage used by a 6000 series electric strike?
Resolution:
For all models of 6000 series electric strike, except the 6300 & 6400, the color of the solenoid wires determine the voltage. Black wires are used on 24VDC solenoids and yellow wir...:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...:
Can the 6000 series strikes be used outside?
Resolution:
None of our 6000 series electric strikes are rated for exterior applications where the strike is fully exposed to the elements. If they were to be used in that situation and the elements caus...:
How hot do the 6000 electric strikes get?
Resolution:
If the solenoid of the 6000 series electric strike is powered continuously with proper voltage at room temperature, the solenoid can feel very warm to the touch. Ensure the power supply ...:
What is a Von Duprin 893P strike?
Resolution:
The 893P is not a strike, it is the UL label on a 6000 series strike. This label will not describe the strike you have.: