chexit electrical template

RELATED FAQS

Question
Answer
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached https://us.allegion.co...
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm  with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...
The 4041 Rw/PA and the Hw/PA have the same template.  The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...
This is possible.  A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...