chexit electrical template
”
RELATED FAQS
Question
Answer
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
Why is the electric E996L-FSE trim used with a Chexit CX99 exit device?
Resolution:
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...:
Where can Von Duprin 6300 electric strike installation instructions or templates be found?
Resolution:
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached https://us.allegion.co...:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
Resolution:
This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...: