The AD lock battery pack type can be changed following this procedure:1. Disconnect the existing battery pack2. Depress and hold the SCHLAGE button for a few seconds to drain off any residual...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels.
- These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
4 Battery Holder
New batteries = 6.2 VDC
Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
8 Battery Holder
New batteries = 12.4 VDC
Low battery threshold is 7.2 VDC
Critical battery threshold is 6.9 VDC
Coin cell = new/...
CO2004 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO200 & CO250 Disable coin cell Nuisance delay and blink,
With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Dynamic Channel Switching is a feature of the Schlage AD-series wireless access point modules. Dynamic Channel Switching (DCS) increases the robustness of the wireless RF communication in a noisy r...
Here is a Technical Note on what Dynamic Channel Switching is, what it improves, how to set-up, and frequently asked DCS questions. DCS Tech Note here
Setting Dynamic Channel Switching 1) Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details 2) Under “PIM Properties” and the “Edit” tab is ...