center case conversion

RELATED FAQS

Question
Answer
This is available.  You will need the SD center case kit, SD center case cover, SD cylinder dog housing, and EL/QEL conversion kit.
No, the fire rated 33A/35A centercase is different than the standard 33A/35A centercase.
SD, Special Dogging
The 250DT is a dummy touchbar for both the 24 and 25 devices.  It is a dummy bar with end caps on each end, no center case.
The UL fire label is only applied to the device center case cover at the factory when the device is built.  This label can not be sold or replaced with a new one.
Von Duprin does not offer the old two piece center case cover any longer. The new center case cover will work on the old two piece cover device. Order the following parts: New 1-piece cover ...
The new 33A/35A center case will not work with the old 33/35 series exit devices.   It is never intended to use parts to convert a device from one Series to another Series as this w...
19-R centercase part number is 650307. F-19-R centercase part #650374.
19-R part# 650384 19-V part# 650385
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
Yes, the holes on the door would be covered up by the 25-R-L device.
The (4) center case mounting holes are in the same location but there are some small modifications that will be needed like the 3/4" dia. hole at device CL for the main cam clearance shown o...
The (2) mounting studs on the 914KIL or 914KIL-IC changed from 3 1/2" center to center to 4 1/2" CTC in April 2002 to follow a device center case change. Due to this, an older device prior to April...
A Knox-Box or Fire Department 911 Box is a small wall-mounted safe that holds building keys for Fire Departments, Emergency Medical Services, and sometimes police to retrieve in emergency situation...