can you use nl-op with mortise panic
”
RELATED FAQS
Question
Answer
Does Von Duprin supply the 9875, 9975, 9875-F and 9975-F mortise exit devices with NL-OP trim function?
Resolution:
For night latch function with pull by others, the 98/99 series mortise exit device should be ordered as NL less trim, e.g., 9875NL-L/TRIM. We will furnish a device only, and the mortise cyl...:
What cylinder does the 512 TP NL use?
Resolution:
A 1-1/8 through 1-1/2" mortise cylinder with straight cam per Step 4 of 512NL Instructions.:
What cylinder is used for the Falcon 510L and 510L-NL trim?
Resolution:
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...:
How can the Von Duprin 98/9975-L with 996L classroom trim function be converted as a night latch function in field?
Resolution:
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as se...:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
Resolution:
This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...:
Do I have to use the 388 to get NL-OP on a 33A/35A series device?
Resolution:
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.The 33A/35A de...:
MORTISE PANIC DEVICE
Resolution: