can we use storeroom function trim for EL Device

RELATED FAQS

Question
Answer
The 510L can be converted to a nightlatch 510L-NL by changing out a few parts to the trim. See 510L to 510L-NL conversion instructions for required parts that will need to be added/r...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
EL is Electric latch retraction and retract the latch bolt into the exit device center case.  E references the electric unlocking of the Pull Side trim for a Panic Device.   With the E function, th...
Application is based on how the door will be used.   Please contact Product Support at 877-671-7011 to discuss your application and select the correct device for your opening.
Place any new orders per the following table ...
 Mortise Deadbolt Locks  Discontinued  Replace With  CO200MD  70-Classroom/Storeroom  40-Privacy  CO250MD  70-Classroom/Storeroom  40-Privacy  AD200MD  70-Classroom/Storeroo...
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software.  The software then decides what action should or should not be taken at the device. 
Von Duprin 98/99 NL drive screw is located in back of the 98/99 center case assembly. NL drive screw should be left in with trim lock slide plate in up position in the 98/99 exit device with E99...
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...