There is not a fire rated version of the Von Duprin 33A/35A rim device.
Only the vertical rod devices (33/3527A-F, 33/3547A-F, 33/3548A-F) can be fire rated.
No, dogging cannot be added to a fire-rated mechanical exit device. Fire rated devices can be only electronically dogged and drop during fire activation.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F, 8875-F or...
The UL fire label is only applied to the device center case cover at the factory when the device is built. This label can not be sold or replaced with a new one.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.
L, B, CE, T and CE-Series doors are available factory prepared
Door...